Chapter 4, Section 3
Part of AM Radio Facts and Trivia: The AM Broadcast Band in the USA. Updated November 15, 2026.
Before high-voltage rectifiers existed, an AM station that needed thousands of volts of clean direct current to drive its transmitting tubes did the only thing it could: it spun a machine. A motor-generator set, an AC motor bolted on a common shaft to a DC generator, was the beating heart of the power plant in the early transmitter hall.
What the tubes demanded. A vacuum-tube AM transmitter needs high-voltage DC on the plates of its tubes: thousands of volts, and for a powerful station, tens of kilowatts of it. Just as important, that DC has to be clean. Any ripple riding on the plate supply modulates the carrier and comes back out of every receiver in the coverage area as hum. In the 1920s there was simply no practical, efficient way to rectify utility AC into that much clean high-voltage DC.
Why a spinning machine. The cleanest high-voltage DC available came from rotating machinery. An AC motor turned a DC generator whose commutator produced smooth, low-ripple DC at whatever voltage the generator was wound for. Because that output was inherently smooth, only modest filtering was needed: a decisive advantage in an era when filtering many kilovolts was bulky and expensive, and when hum was the constant enemy of a clean signal.
When they ruled the transmitter hall. Through the 1920s and into the 1930s, the motor-generator set was the de facto standard for transmitter DC. The first machines pressed into broadcast service rarely exceeded about 1,500 volts; but as station power climbed, builders demanded far more, and by the mid-to-late 1920s motor-generators wound for upwards of 18,000 volts were being built specifically for radio service. These were held to a tighter standard than ordinary industrial generators: even a slight voltage perturbation could not be tolerated, because it would ride straight out onto the air.
What a 50,000-watt plant required. A 50 kW transmitter was a serious industrial installation, and the motor-generator set sat at the center of it. The plate supply alone had to deliver well over the station’s carrier power as clean DC; the big water-cooled final tubes drew low-voltage filament current measured in the hundreds of amperes; and distilled water was circulated through the tubes to carry away the heat. The diagram below shows the shape of the whole plant.
Drawing 4.3-1
What replaced them. Two changes retired the spinning plate supply. First, the hot-cathode mercury-vapor rectifier tube matured through the late 1920s and 1930s and could make high-voltage DC directly from AC, smaller, cheaper, and far more efficient than a room-sized machine, though the tubes had to be carefully “conditioned” before service. Then, from the 1960s, solid-state silicon rectifier stacks replaced the rectifier tubes in turn.
The motor-generator’s one lasting virtue (inherently clean, hum-free DC) was the very problem that better rectifiers and better filtering eventually solved by other means.
Sources: Radio World, "How Transmitter Power Supplies Evolved" and "They Put the Juice in Powerful Radio" (James O’Neal); general AM broadcast-engineering history. Values shown are representative of the era rather than of any one transmitter.
© 2026 Chris, N6JET. Free to read and share for non-commercial use with credit (Creative Commons BY-NC 4.0). Not for sale.
All AM radio stories by subject · AM radio interactive tools and simulators · AM Trivia Challenge quiz