Chapter 5, Section 2

Why Every AM Transmitter Site Has a "Jesus Stick"

Part of AM Radio Facts and Trivia: The AM Broadcast Band in the USA. Updated November 15, 2026.

Walk into any AM transmitter building and look just inside the rear door of the transmitter cabinet. Hanging there, almost always, is a fiberglass rod with a metal hook on the end and a heavy braided cable running from it to the station ground. Broadcast engineers call it the Jesus stick, because it's the thing standing between you and meeting Him. Its polite name is a grounding stick or shorting stick; its job is to drain the lethal charge out of a transmitter before you put your hand inside.

Why the charge is still there after you flip the switch. An AM transmitter runs its final amplifier on a high-voltage DC supply: thousands of volts, and on a big 50 kW rig well into the tens of kilovolts. To smooth that DC, the supply uses large filter capacitors, and a charged capacitor doesn't care that you've switched the transmitter off. It can sit there holding a killing charge for minutes or longer after the power is gone. Most supplies have bleeder resistors meant to drain the caps automatically when the high voltage drops, but bleeders fail, quietly, and you have no way to know one has failed by looking. So the iron rule of every transmitter shop is the same: never trust the bleeder. The capacitor is assumed live until you have personally shorted it to ground.

How it's used. One end of the stick is bonded permanently to the station ground, the same copper that ties the whole site to earth. The other end, the hook, rides on the insulated handle. After shutting the transmitter down and opening the cabinet, the engineer reaches in with the stick and touches the hook to every high-voltage node in turn (each capacitor terminal, the plate cap, the supply output) draining each one to ground. Better sticks have a current-limiting resistor for the first touch (to soften the discharge) and then a hard, dead-short ground for the second. If a bleeder had failed and a cap was still charged, you find out the safe way: a loud, startling SNAP and a blue flash at the hook: the sound of the shock you didn't take. And even after all that, the discipline holds: you never assume the stick did its job. You verify with a meter before a finger goes near anything.

The other names. The Jesus stick goes by several shop names, each telling you something about the people who coined it:

NameWhere it comes from
Jesus stickIt's what's between you and meeting Jesus: skip it and you may make the introduction
Chicken stickYou'd be a fool not to be "chicken" around a charged HV supply
Shorting / grounding stickThe plain-English name: what it literally does
Brinkley stickThe British radar term, from RAF tradition; named after Charles Brinkley, an amputee ferryman who carried radar crews across the River Deben (no relation to the goat-gland Dr. Brinkley of the border blasters)

Table 5.2-1

The trivia. The Jesus stick is the most low-tech object in a building full of precision RF gear (a stick, a hook, and a wire) and it is arguably the most important. It exists because the same site that once had a lone operator on duty around the clock, hand-cranking a phasor full of high-voltage RF, was a place where one careless reach into a cabinet could be the last thing you ever did. The transmitters got safer and the staffing went away, but the stick still hangs inside the door of every transmitter on the dial, because a filter capacitor in 2026 holds its charge exactly as hard as one in 1946.

Sources: Wikipedia (Brinkley stick) · WorldwideDX / broadcast-engineering forums (capacitor discharge / "Jesus stick" practice) · U.S. Patent 7,834,487 (shorting stick for safing high-voltage equipment).

THE JESUS STICK: THE LAST TOOL YOU TOUCH BEFORE THE CABINET THE TOOL (hanging where it lives) inside of the transmitter's rear door DANGER: HIGH VOLTAGE GROUND ALL CAPACITORS BEFORE SERVICING station ground bus insulating fiberglass rod metal hook: this end touches every terminal heavy braided copper straight to station ground THE MOMENT IT EXISTS FOR PA tube HV filter caps: the charge hides here bleeder resistor (open: failed!) CRACK! The cap was still charged hand stays on the insulated end THE RITUAL: EVERY TIME, NO EXCEPTIONS 1. Kill the plate voltage. Open the breaker. 2. Hook EVERY high-voltage point: caps, bus, tube anode: and let each one snap to ground. 3. Leave the hook clamped on the bus while your hands are inside. Trust the stick, never the bleeder.

Why the dramatic name is earned. Killing a transmitter doesn't make it safe: the high-voltage filter capacitors can hold a charge of thousands of volts after shutdown, and the bleeder resistors that are supposed to drain them are exactly the kind of part that fails silently: you find out the moment your hand finds the terminal. The grounding stick is the zero-trust answer. The engineer's hand never leaves the insulating fiberglass; the metal hook visits every capacitor, bus bar, and tube anode; and the heavy braid dumps whatever charge is hiding straight into the station ground, sometimes with a rifle-crack and a flash that is the sound of an accident not happening. The discipline is in the sequence shown above, and in the placement: the stick hangs inside the rear door, where reaching past it without using it requires a deliberate act of foolishness. The nickname survives because the lesson does: it's the thing standing between a routine repair and meeting its namesake.

Drawing 5.2-2

More AM Radio Stories

AM Radio Facts and Trivia, the main page, with hundreds more records, oddities and firsts. Test yourself with the AM Trivia Challenge.

More in Lightning, RF and Safety

All AM radio stories by subject · AM radio interactive tools and simulators · AM Trivia Challenge quiz

© 2026 Chris, N6JET. Free to read and share for non-commercial use with credit (Creative Commons BY-NC 4.0). Not for sale.